Add 64-bit INT to Modbus Driver
Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Created 31 Aug 16:02
Drivers / Protocols
1
15
Vote
Add my vote +1
+2
+3
+4
+5
Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !
As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Created 28 Apr 08:42
Development Tools
0
33
Vote
Add my vote +1
+2
+3
+4
+5
Search and replace inside Equipment Editor
When we have diferent equipments with same comun branch and need to change them all, its a lot of work, because we need t go to each equipment open it search the item, open it and change.
Created 23 Mar 10:44
Development Tools / Equipment
0
Future Consideration
13
Vote
Add my vote +1
+2
+3
+4
+5
Process Analyst in dark mode
A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Created 26 Jul 08:55
Alarms
2
Future Consideration
22
Vote
Add my vote +1
+2
+3
+4
+5
Alarm Page and Historical SOE list with Time filter
We are getting complaints from customer that the Alarm Page and Historical SOE do not have to capability to filter lists on Time. This case has been discussed in the Community . And there has been several feedbacks form the Community to AVEVA on t...
Created 03 Nov 08:25
Historic Data / Storage
2
9
Vote
Add my vote +1
+2
+3
+4
+5
Better keyboard support in Graphics Builder
A lot of potential Graphics Builder tasks can be repetitive, and can be sped up using a keyboard instead of a mouse. But some dialogues are not keyboard friendly. The specific case I have in mind is Tools -> Swap Colours. Opening it from the ke...
Created 27 Feb 13:55
Graphics / Visualization
1
15
Vote
Add my vote +1
+2
+3
+4
+5
Citect Studio - Insert Row, Insert Rows
There is no option to insert a new row record. Such an option could be useful. This can be done by DBF addin excel.
Created 16 Dec 09:05
Development Tools
0
28
Vote
Add my vote +1
+2
+3
+4
+5
Add 'Go To Definition' in Cicode Editor
Allow the user to right click on a User Defined Cicode Function within a code segment and select 'Go To Definition' to navigate to the selected function definition. Optionally provide the ability to select 'Back' to navigate to last cursor positio...
Created 17 Apr 02:19
Development Tools
0
Future Consideration
12
Vote
Add my vote +1
+2
+3
+4
+5
Process Analyst - Bar graph
It would be good to add also bar graph trends.
Created 17 May 13:29
Alarms
0
Future Consideration
19
Vote
Add my vote +1
+2
+3
+4
+5
Respect user input from printform when selecting landscapemode
I've a customer that needs to print trends with 5 different vertical scales and therefore use the old TrendDsp functions. (Process analyst only supports 2 vertical scales). The Customer want to print these trends and selects a printer, color mode ...
Created 08 Nov 14:07
Alarms
0