Logging Citect alarm in Wonderware Historian
Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Created 1 Jun 08:19am
Alarms
In Roadmap
7
Vote
Add my vote +1
+2
+3
+4
+5
Bundle UA Server Expert Instead of OFS with PlantSCADA
OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Created 30 Jan 05:03am
Drivers / Protocols
Future Consideration
33
Vote
Add my vote +1
+2
+3
+4
+5
Search and replace inside Equipment Editor
When we have diferent equipments with same comun branch and need to change them all, its a lot of work, because we need t go to each equipment open it search the item, open it and change.
Created 23 Mar 10:44am
Development Tools / Equipment
Future Consideration
15
Vote
Add my vote +1
+2
+3
+4
+5
Process Analyst in dark mode
A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Created 26 Jul 08:55am
Alarms
Future Consideration
7
Vote
Add my vote +1
+2
+3
+4
+5
Alarms changes can be pushed to runtime without [Alarm]UseConfigLimits=1
When making alarm changes, sometime you will notice the change does not go through to runtime if you currently have [Alarm]UseConfigLimits=0 This is because the alarm server reads from the database instead of the rdb files, failing to recognize th...
Created 19 Dec 10:27pm
Alarms
Future Consideration
22
Vote
Add my vote +1
+2
+3
+4
+5
Alarm Page and Historical SOE list with Time filter
We are getting complaints from customer that the Alarm Page and Historical SOE do not have to capability to filter lists on Time. This case has been discussed in the Community . And there has been several feedbacks form the Community to AVEVA on t...
Created 3 Nov 08:25am
Historic Data / Storage
Reviewed & Categorized
13
Vote
Add my vote +1
+2
+3
+4
+5
Add 64-bit INT to Modbus Driver
Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Created 31 Aug 04:02pm
Drivers / Protocols
Reviewed & Categorized
29
Vote
Add my vote +1
+2
+3
+4
+5
Add 'Go To Definition' in Cicode Editor
Allow the user to right click on a User Defined Cicode Function within a code segment and select 'Go To Definition' to navigate to the selected function definition. Optionally provide the ability to select 'Back' to navigate to last cursor positio...
Created 17 Apr 02:19am
Development Tools
Future Consideration
15
Vote
Add my vote +1
+2
+3
+4
+5
Citect Studio - Insert Row, Insert Rows
There is no option to insert a new row record. Such an option could be useful. This can be done by DBF addin excel.
Created 16 Dec 09:05am
Development Tools
Reviewed & Categorized
13
Vote
Add my vote +1
+2
+3
+4
+5
Process Analyst - Bar graph
It would be good to add also bar graph trends.
Created 17 May 01:29pm
Alarms
Future Consideration